Catheter design is a trade-off game. Pushability, torque control, kink resistance, lubricity, trackability and X-ray visibility all compete for the same wall thickness and lu...
READ MORE Cur síos:
Buntáistí:
| Catheter a threorú | ||||
| Toise | Fad (mm) | OD (mm) | ID (mm) | Cuar |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | JL-35 |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | JL-40 |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | JR-35 |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | JR-40 |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | EBU40 |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | EBU-30 |
| 5F | 1050 | 1.80±0.03 | 1.50±0.03 | EBU35 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | JL-35 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | JL-40 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | JR-35 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | JR-40 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | EBU40 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | EBU-30 |
| 6F | 1050 | 2.10±0.03 | 1.80±0.03 | EBU35 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | JL-35 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | JL-40 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | JR-35 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | JR-40 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | EBU40 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | EBU-30 |
| 7F | 1050 | 2.40±0.03 | 2.08±0.03 | EBU35 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | JL-35 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | JL-40 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | JR-35 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | JR-40 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | EBU40 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | EBU-30 |
| 8F | 1050 | 2.65±0.03 | 2.30±0.03 | EBU35 |
Níl cur i bhfeidhm an chaitidéar treorach teoranta do chóireáil idirghabhála soithíoch traidisiúnta, ach leathnaíonn sé freisin go réimsí éagsúla leighis mar siadaí, nerves, riospráide, úireolaíocht, etc. Le dul chun cinn leanúnach na teicneolaíochta, tá feidhmeanna na gcaitidéar treorach ag éirí níos mó agus níos sofaisticiúla, rud a d'fhéadfadh cabhrú le dochtúirí diagnóis agus cóireáil níos cruinne a dhéanamh.
Cardashoithíoch: idirghabháil artaire corónach, angaplasty, catheterization cairdiach.
Catheter design is a trade-off game. Pushability, torque control, kink resistance, lubricity, trackability and X-ray visibility all compete for the same wall thickness and lu...
READ MORENuair a chuirtear feiste leighis sa chorp, ní í an chéad cheist ná "an oibríonn sé?" ach "an bhfuil sé sábháilte?" Tá polyetheretherketone (PEIC) tar éis an cheist sin a fhre...
READ MOREAn bhfuil Feadánra PEIC Leighis Biocompatible Aithnítear feadánra PEIC Leighis go ginearálta mar bhith-chomhoiriúnach agus úsáidtear go forleathan é i bh...
READ MORE